Written By: Chris Ruhlin | Last Updated: November 19, 2026
Time to Read 12 Minutes
Underground fuel tanks are out of sight, so most facility managers don't think about them until something goes wrong. A leaking tank can mean soil and groundwater contamination, a cleanup bill that climbs fast, and neighbors or a school next door asking what happened. Pennsylvania built a state fund to help owners handle exactly that, and a lot of tank owners don't know it exists until they need it.
The Underground Storage Tank Indemnification Fund, usually called USTIF, can help pay for cleanup of eligible releases from regulated underground tanks. In this article we'll explain who it covers, what it pays for, what it leaves out, and why reporting a leak quickly and keeping your tank paperwork in order matters so much. We'll also cover what to do now, before a leak, and where aboveground oil storage fits. If you have questions about your own tanks, you're welcome to reach out to RMA.
TL;DR
USTIF is a state fund that can reimburse owners and operators of regulated underground tanks for cleaning up leaks and for third-party claims tied to them. To qualify, the tank has to be registered with DEP, the fund's fees have to be paid, and you have to report the claim within 60 days of learning about it. It doesn't cover tank removal, repairs, or upgrades, and it's built for underground tanks, so don't count on it for aboveground oil storage. The best move is to get your registration and fees in order now and know who to call the day a leak is found.
USTIF was created under Pennsylvania's Storage Tank and Spill Prevention Act to help tank owners meet the financial responsibility requirement for underground tanks. Put simply, owners of regulated tanks have to be able to pay for a cleanup if a tank leaks, and the fund is how many of them do it. It's administered through the Pennsylvania Insurance Department, and it works alongside DEP's storage tank program, which regulates the tanks themselves.
The fund pays claims for two things. The first is corrective action, which is the cleanup work: figuring out the extent and nature of the release, developing a remedial action plan, and doing the reasonable and necessary work to address the contamination. The second is third-party liability, meaning bodily injury and property damage claims that come out of the release, such as a neighboring property owner whose well is affected. It covers releases that occurred on or after February 1, 1994.
The numbers below come from the state's own program information. They can change, so confirm the current figures with USTIF before relying on them for a specific tank.
| Item | What the state program says |
|---|---|
| Per-tank coverage limit | $1.5 million per tank, per occurrence |
| Annual aggregate | $1.5 million for owners with 100 tanks or fewer, $3 million for 101 or more |
| Deductible, corrective action | $5,000 per tank, per occurrence |
| Deductible, third-party liability | $5,000 per tank, per occurrence |
| Releases covered | On or after February 1, 1994 |
The claimant has to be the owner or operator of the tank. A contractor, a past tenant, or a lender can't file in their own right, although certified companies and environmental consultants can help an owner file and manage the claim. For the tank itself, the fund covers regulated underground storage tanks holding petroleum products and certain other regulated substances, including gasoline, new motor oil, and farm diesel. Regulated tanks that hold heating oil, non-farm diesel, kerosene, or used motor oil are covered too.
Underground heating oil tanks get a special rule. Many of them aren't regulated by DEP, and those are only covered if the owner chose to opt in to the program. The opt-in applies to tanks of 3,000 gallons or more used for heating on the premises. If you own a smaller or nonregulated heating oil tank and never opted in, USTIF coverage isn't there for it. We cover how heating oil tanks can also trigger federal rules in our article on heating oil tanks at Pennsylvania businesses.
Whether a buried tank is a regulated underground tank, and how it interacts with the federal oil spill rule, depends on what it holds, how big it is, and how it's used. Our guide on when buried tanks count toward SPCC and when they don't walks through that side of it.
The fund pays for cleanup and third-party claims, not for running or improving your tank system. It doesn't pay for facility upgrades, repair and maintenance work on underground tanks, or tank removal. If you pull a tank out as part of a planned closure and find contamination, the removal is yours to pay for, and the cleanup of an eligible release is where the fund may come in. It also only pays costs considered reasonable and necessary, so an expensive approach to a simple problem can leave you covering the difference.
Tanks that don't meet the eligibility conditions are out as well. An unregistered regulated tank is the clearest example, and we'll come back to that. The fund also isn't a general oil spill program. It's built around underground tanks, so aboveground tanks, drums, totes, and oil-filled equipment aren't what it was designed to cover. If your oil storage is mostly aboveground, plan on paying for spill cleanup yourself or through your own insurance, and check your policy language, since many general liability policies limit pollution coverage.

Claims have to be reported within 60 days after you learn of a potential claim, and the state is direct that coverage will be denied if you miss that window. The clock starts when you have knowledge of a potential problem, which can be earlier than the day a consultant confirms contamination. A failed tightness test, a loss of product that doesn't add up, or fuel showing up where it shouldn't all count as reasons to pick up the phone. The state asks owners to contact the USTIF Claims Unit immediately after a release, and you can do that through your account on the USTIF website or by phone. Confirm the current phone numbers on ustif.pa.gov, because the state's own pages list more than one.
After you report, the fund confirms the claim, and a claim representative reaches out quickly to start an investigation. Expect them to ask for your release detection records and a recorded statement. The fund's administrator then reviews the claim and recommends whether you're eligible, and you receive a written determination. Eligible claims get payment instructions, and denied claims get information on how to appeal. Some eligible cleanups are advertised for competitive bidding by remediation contractors.
The process also has a money side that surprises people. You generally contract with your environmental consultant directly, pay the bills, and then seek reimbursement for approved costs, although the fund may pay approved invoices straight to the consultant as a convenience. Make sure your finance contact knows that before the first invoice arrives.
A leak also usually triggers duties that have nothing to do with USTIF. Depending on what leaked and where it went, you may have to report to DEP and, in some cases, federal agencies, and you'll need to stop the release and protect people and waterways first. Our article on the sheen rule and oil spill reporting covers the federal side. Releases with injuries, third-party property damage, or enforcement attention are also the kind of situation where talking to an environmental attorney can make sense.
Most denied claims come down to paperwork, not the leak itself. The state lists the conditions plainly. The fund's fees have to be paid, the tank has to be registered with DEP (unless it's an opted-in heating oil tank), any required permit has to be in place, and you have to be able to show the release happened on or after February 1, 1994. You also have to cooperate with the investigation, including defending suits and responding to the fund's requests, and you have to meet the reporting requirements.
Registration is where facilities get caught. Pennsylvania courts have heard several cases from tank owners whose claims were denied because a tank wasn't registered or the fees hadn't been paid when the release was found. Those disputes were fought over the details of the statute, and owners who ended up there spent real time and legal money on them. The simpler path is to never be in that position. Know which of your tanks are registered, keep the DEP registration paperwork somewhere you can find it, and make sure the annual fees get paid. Our article on the PA DEP storage tank registration certificate explains what that document is, and our piece on tank registration fees and other costs facilities forget covers the money side.
Leak detection records matter too. The fund asks for them during the investigation, so a facility that can't show monthly monitoring or testing records starts the claim at a disadvantage. If your records live in one person's desk drawer, that's worth fixing this month.
Start with an inventory. List every tank on the property, whether it's above or below ground, what it holds, how many gallons it can hold, who owns it, and whether it's registered with DEP. Include old tanks nobody uses anymore, since an abandoned underground tank can still be your responsibility. If you bought or leased the property, don't assume the previous owner handled registration.
Next, check the fee and registration status of each underground tank against DEP and USTIF records, and fix gaps before a release forces the question. Then write down who gets called when a leak is suspected, including the USTIF Claims Unit, your environmental consultant, and your insurance contact, along with the 60-day reporting window. A one-page contact sheet taped inside the tank room costs nothing and saves hours on a bad day.
Then look at the aboveground side, which USTIF doesn't help with. Federal oil spill rules apply to facilities that store more than 1,320 gallons of oil aboveground, counting only containers of 55 gallons or more, or more than 42,000 gallons buried. If you cross that line, you'll need a Spill Prevention, Control, and Countermeasure plan, usually shortened to an SPCC Plan. That's a written plan that describes your oil storage, the containment and inspections that prevent spills, and how you'd respond to one. If you already have an SPCC Plan, it needs to stay current as tanks are added, removed, or moved. Our overview of what an SPCC Plan is is a good starting point, and Pennsylvania facilities with larger aboveground tanks may also face a separate state plan, which we explain in our PPC Plan article.
Pennsylvania's attention to tank leaks has a long history. The 1988 collapse of a large aboveground tank at Floreffe sent diesel into the Monongahela River and shaped much of the state's current storage tank program. If you're curious how that event still shapes the rules you follow today, we wrote about it in the Floreffe spill article. You can also browse everything we've published on the topic in the SPCC resources library.
We're a family-run firm, and the people who talk with you are the people doing the work. We don't handle tank installation, tank removal, or cleanup contracting, and we don't file USTIF claims for owners. What we do help with is the compliance side of oil storage: figuring out whether your facility needs an SPCC Plan, building or rebuilding one, and helping you understand which oil storage rules apply to your site so there are fewer surprises later. If you're not sure whether a tank on your property is regulated, we'll tell you honestly where to look and when you can sort it out yourself without us.
There's no pressure and no obligation. You can call us, email, or fill out the form on our website, and if it makes sense to talk with RMA about your oil storage, we'll walk through it with you.
Understand the SPCC Plan and related oil storage requirements in Pennsylvania, including tank regulations, Tier II reporting, and stormwater permits for oil facilities.
Not sure whether your facility needs an SPCC Plan? Have an existing plan that's due for review? Or do you already know you need one and just want to get the project moving?
Tell us a little about your Pennsylvania facility, the oil you store, and what you're trying to accomplish.
RMA can help you understand which requirements apply, whether you need a new plan or an update, what the project would involve, and what it may cost.
There's no need to have everything figured out before reaching out. That's what we're here to help with.
Want to dig deeper? Check out these additional resources to get a clearer understanding of the SPCC world and how it applies to your facility.
Tags: Pennsylvania SPCC Plans
Whether you need help with a single requirement or want to hand off your entire environmental program, we get it done right, the first time. You'll feel protected, confident in your company's regulatory standing, and ready for whatever comes next.
Tel: 888-RMA-0230 | Email: info@rmagreen